SENSORS

MODEL 3003 : Analog Output Evaporation Gauge

General Description

The Model 3003 Analog Output Evaporation Gauge is used to determine the evaporation rate by measuring the changing water level in an evaporation pan. A standard Class A National Weather Service evaporation pan is recommended.

The instrument consists of a float, pulley, and counterweight attached to a precision 1000-ohm potentiometer mounted through a gear assembly in a weatherproof housing. The triangular base plate is equipped with three leveling screws. The potentiometer produces a resistance output proportional to the position of the float which can be monitored on site using a data logger or a strip chart recorder, or remotely using HydroLynx Data Transmitters.

Options

N/A

Specifications

MODEL 3003 : SPECIFICATIONS

Gauge
Height: 27½ in.
Diameter: 8 in.
Base Dimensions: 16 in. triangle with leveling screws
Float: 4 in. dia. Polystyrene
Cable and Connector: 3-pin ms connector
Total System Resolution: 0.0098 in. w/ 5096 Trans.

Potentiometer
Accuracy: 1%
Rotation: Continuous
Resistance: 1000 ohms
Operating temperatures: -40 to 60 °C
Linearity: 0.25%
Range: 0-10 in.
Water Input Port: ½ in. NP coupling, female
Weight: 7½ lbs.
Shipping Weight: 30 lbs.

 

Ordering Information

3003
Evaporation Gauge

  • 1000 Ohm Potentiometer
  • 50 ft. Cable with MS Connector

3003P/F
Connecting Pipe and Fittings

  • 10 in. Connecting Pipe
  • Fittings for Attaching to Evaporation Pan
Solar Radiation Shield

GET IN TOUCH

Call us at 1-916-374-1800